Guangzhou Leite Electronic Technology Co., Ltd.

50m lightning protection tower, national standard lightning protection tower, Guangzhou lightning protection tower, park lightning protection measures, army lightning protection grounding, Zhongshun lightning protection device

Security Exhibition Network

14

contact number

13902217373

Your location:
Guangzhou Leitai Electronic Technology Co., Ltd. > Lightning Rod > Pre-discharge Lightning Rod > Photoelectric Lightning Rod
QQ chat
Products

Photoelectric lightning rod

  • company name:
  • Updated:
  • location:
  • Production address:
  • Views:
  • Guangzhou Leite Electronic Technology Co., Ltd.
  • 2017-04-20 10:01:24
  • Guangzhou City
  • 774

I want to inquire

【a brief introdction】

Lightning protection device consisting of lightning receptor, down conductor and grounding device. The air-termination device is installed on the structure and is higher than the protected object. The load is sensed by Thunder Cloud in advance and the energy is released through the down-conductor to weaken the energy of the Thunder Cloud to protect the building. Photoelectric lightning rod

【Detailed description】

When a lightning cloud layer is formed, an electric field is generated between the cloud layer and the ground, and the electric field strength can reach 10kV / m or even higher. As a result, corona discharge began to appear on the raised parts of the ground or on metal parts. When a descending leader is formed inside the thunder cloud, lightning strikes begin. The descending pilot charge moves to the ground in a staircase. As the descending leader approaches the ground, it will issue an upward facing leader from the more prominent part of the ground. When the head-on leader meets the down-going leader, a strong “neutralization” process occurs, and a large current (tens to hundreds of thousands of amperes) appears. This is the main discharge phase of the thunderbolt, accompanied by thunder and flashes. Other buildings on the ground may generate several head-on pilots. The * oncoming leaders meeting with the descending pilot determine the location of the lightning strike. The working principle of the pre-discharge lightning rod is to generate a head-on pilot faster than the ordinary lightning rod. Before the formation of the natural on-the-spot leader, an early discharge lightning rod will take the lead to generate a leader, which will quickly propagate in the direction of the lightning until the lightning is captured and introduced into the ground. It has been confirmed in the laboratory that this start-up preemption time, which produces the on-off pilot earlier than the ordinary needle, is called △ T, which gives a more effective lightning protection function to the lightning rod in advance. Photoelectric lightning rod
1. Installation of the lightning rod After the lightning rod components are assembled, the lightning rod is fixed on the base with bolts or welding. 1) When connecting lightning rods, connect them reliably. 2) After the installation is completed, the connection of the lightning rod or the coating on the metal surface is damaged, and the rust prevention treatment should be done. Photoelectric lightning rod
2. Maintenance of lightning rods After the lightning rods are put into use, they should be inspected before the thunderstorm season according to the following: 1) The connections of the connecting parts of the lightning rods should be reliable and must not be loosened. 2) Check the total resistance of the lightning rod lightning receptor to the base ≤ 5Ω. 3) The lightning rod should be grounded through a down-conductor (dedicated or borrowed), and the grounding resistance is ≤10Ω. In areas with high soil resistivity, the requirements for ground resistance can be appropriately relaxed.
3. The protection range of the lightning rod The protection range of the lightning rod should be calculated according to the method specified in appendix IV of the "ball rolling method to determine the protection range of the lightning receptor" in GB50057-94 "Code for Design of Lightning Protection of Buildings". If it fails to meet the design requirements, you can raise the lightning rod by adding a post, or choose to discharge the lightning rod in advance. When the range of protection objects is wide, consider using multiple lightning rods to meet the design requirements.

Message box
Interested product: *
Message content: *
Your Name: *
Your unit: *
contact number: *
Common mailbox: *
Address:
province: *
Verification code: * = Please enter the calculation result (fill in Arabic numerals), such as: three plus four = 7
product search

Please input product keyword:

contact details
Address: Guangzhou. Liwan. Huanhua Road. 27 Huannan East Street
Postcode: 510370
Contact: Mr. Zhang
Phone: 020-81504548
Fax: 020-81504548
Mobile: 13902217373
Message: Send message
Personalization: www.fang-lei.com
Website: www.leitai.net
Shop: http://www.fashionpho.com/st3037/
| Shop Home | Company Profile | Products | Latest Supply | Company News | Inquiry Message | Contact Us | Member Management |
Designed and produced by Security Exhibition Network. Reproduction without permission will be investigated. Copyright (C) http://www.fashionpho.com , All rights reserved.
The above information is provided by the enterprise itself, and the authenticity, accuracy and legality of the information content are the responsibility of the relevant enterprise. Security Exhibition Network does not assume any responsibility for this.
Tips: In order to avoid purchasing risks, it is recommended that you confirm the supplier's qualification and product quality before purchasing the product.
QR code online chating

Scan to visit mobile station